International Journal of Osteopathic Medicine
Volume 10, Issue 2 , Pages 65-79, June 2007

An observational study of motion induced in the lumbar–pelvic complex during ‘harmonic’ technique: A preliminary investigation

School of Health Science, Unitec New Zealand, Private Bag 92025, Auckland, New Zealand

Received 1 December 2006; received in revised form 18 June 2007; accepted 26 June 2007.

Abstract 

Background

In manual therapy, the ‘harmonic’ approach to inducing cyclical motion in different body regions has been described as distinct from rhythmic articulation, ‘harmonic’ techniques being further defined as those that bring about a state of resonance in body tissues. During application of ‘harmonic’ techniques, resonance is proposed to result from the technique operator ‘tuning in’ to the inherent frequency of the oscillating region. This study provides a quantitative analysis of the motion induced by a ‘harmonic’ technique and the notion of ‘tuning in’.

Objectives

To provide a quantitative analysis of the oscillatory motion induced in the lumbar–pelvic complex by the application of a ‘harmonic’ technique and to compare the motion induced by two different operators.

Methods

A ‘harmonic’ technique was applied to the lumbar–pelvic complex of 26 volunteers and the oscillatory motion filmed. An additional operator performed the technique on a subgroup (n=12) of the sample to provide data for the comparisons of two operators.

Results

The mean (SD) frequency of oscillation across all sessions was 1.17Hz (0.10). The mean (SD) amplitude was 0.15m (0.03). The mean (SD) inter-cycle variability of period was 2.45% (0.47). The mean (SD) inter-cycle variability of amplitude was 6.35% (2.06). There were no consistent intra-cycle relationship identified between period and amplitude. There was an inverse relationship between frequency and subject weight (Pearson's r=−0.66 (95% CI −0.84 to −0.32). The intra-class correlation coefficient (ICC) for inter-operator reliability of frequency was 0.93 (95% CI=0.83 to 0.97). The ICC for inter-operator reliability of amplitude was 0.87 (95% CI=0.69 to 0.94).

Conclusion

The motion induced in the lumbar–pelvic complex using a modified harmonic technique displayed properties of harmonic motion. The inter-operator study demonstrated that two operators of different morphologies ‘tuned in’ to the same frequency of individual subjects. This supports the theory that motion arising from harmonic techniques is resonant.

Keywords: Osteopathy, resonance, harmonic technique

To access this article, please choose from the options below

Login to an existing account or Register a new account.

  • Purchase this article for 31.50 USD (You must login/register to purchase this article)

    Online access for 24 hours. The PDF version can be downloaded as your permanent record.

  • Subscribe to this title

    Get unlimited online access to this article and all other articles in this title 24/7 for one year.

  • Claim access now

    For current subscribers with Society Membership or Account Number.

  • Visit SciVerse ScienceDirect to see if you have access via your institution.
 

PII: S1746-0689(07)00046-6

doi:10.1016/j.ijosm.2007.06.004

International Journal of Osteopathic Medicine
Volume 10, Issue 2 , Pages 65-79, June 2007